Phani, Kalyan Kumar and Bose, Nripati Ranjan (1986) Hydrothermal aging of CSM-laminate during water immersion - an acoustoultrasonic study. Journal of Materials Science, 21 (10). pp. 3633-3637. ISSN 0022-2461
PDF
- Published Version
Restricted to Registered users only Download (663Kb) | Request a copy |
Abstract
Acousto-ultrasonics represents a very attractive and promising technique for detecting flaws and studying degradation of composite material. Studies of damage under hydrothermal ageing incurred by random fibre-reinforced laminates have been carried out with this technique. It is shown that the “stress wave factor” is a sensitive indicator of random fibre composite strength reduction due to a hydrothermal effect. The same study can be used for the estimation of strength from the data generated under accelerated conditions.