Singh, Ankush Pratap and Rana, Masud and Pal, Bidyut and Datta, Pallab and Majumder, Santanu and Roychowdhury, Amit (2023) Patient-specific femoral implant design using metamaterials for improving load transfer at proximal-lateral region of the femur. Medical Engineering & Physics, 113. Art No-103959. ISSN 1350-4533

Full text not available from this repository. (Request a copy)

Abstract

Loading configuration of hip joint creates resultant bending effect on femoral implants. So, the lateral side of femoral implant which is under tension retracts from peri-implant bone due to positive Poisson's ratio. This retraction of implant leads to load shielding and gap opening in proximal-lateral region, thereby allowing entry of wear particle to implant-bone interface. Retraction of femoral implant can be avoided by introducing auxetic metamaterial to the retracting side. This allows the implant to push peri-implant bone under tensile condition by virtue of their auxetic (negative Poisson's ratio) nature. To develop such implants, a patient-specific conventional solid implant was first designed based on computed-tomography scan of a patient's femur. Two types of met-amaterials (2D: type-1) and (3D: type-2) were employed to design femoral meta-implants. Type-1 and type-2 meta-implants were fabricated using metallic 3D printing method and mechanical compression testing was conducted. Three finite element (FE) models of the femur implanted with solid implant, type-1 meta-implant and type-2 meta-implant were developed and analysed under compression loading. Significant correlation (R2 = 0.9821 and R2 = 0.9977) was found between the experimental and FE predicted strains of the two meta-implants. In proximal-lateral region of the femur, an increase of 7.1% and 44.1% von-Mises strain was observed when implanted with type-1 and type-2 meta-implant over the solid implant. In this region, bone remodelling analysis revealed 2.5% bone resorption in case of solid implant. While bone apposition of 0.5% and 7.7% was observed in case of type-1 and type-2 meta-implants, respectively. The results of this study indicates that concept of intro-duction of metamaterial to the lateral side of femoral implant can prove to provide higher osseointegration-friendly environment in the proximal-lateral region of femur.

Item Type: Article
Subjects: Engineering Materials
Divisions: UNSPECIFIED
Depositing User: Bidhan Chaudhuri
Date Deposited: 05 Oct 2023 09:53
Last Modified: 05 Oct 2023 09:53
URI: http://cgcri.csircentral.net/id/eprint/5564

Actions (login required)

View Item View Item